AtaGenix Laboratories

Home - Featured Products - Featured Kits

cGMP ELISA Kit | High-Sensitivity Detection

Catalog Number: ATK00050

Product Description

cGMP and cAMP are small cyclic nucleotides that act as intracellular second messengers. cGMP is synthesized by guanylyl cyclase and degraded by phosphodiesterase, playing a critical role in physiological and pathological processes, including cardiovascular function and the regulation of visual and olfactory systems.

The cGMP ELISA Kit uses a competitive enzyme-linked immunoassay (ELISA) method to measure cGMP levels in biological samples. The assay involves competition between HRP-conjugated cGMP and sample cGMP for binding to anti-cGMP monoclonal antibodies. Absorbance at 450 nm is inversely proportional to cGMP concentration. The kit features high sensitivity with an IC50 of ~10 pmol/mL and a detection limit of ~0.1 pmol/mL.

Experimental Overview

  • Catalog No: ATK00050
  • Detection wavelength: 450 nm (reference 630 nm)
  • Sensitivity: 0.1 pmol/mL
  • IC50: ~10 pmol/mL

Components & Storage

Component Details Storage
cGMP Standard 10000 pmol/mL, 1x0.1mL -80°C
cGMP-HRP 1000x HRP conjugated with cGMP, 1x0.02mL -80°C
cGMP Antibody Anti-cGMP monoclonal antibody (1000x), 1x0.02mL -80°C
10x Assay Buffer Phosphate buffer with preservative, 1x30mL 2-8°C
Neutralizing Reagent Tris buffered saline with preservative, 1x8mL 2-8°C
Sample Diluent 0.1M HCl, 1x30mL 2-8°C
TMB Substrate 3,3’,5,5’-Tetramethylbenzidine, 1x18mL 2-8°C
Stop Solution 2M sulfuric acid, 1x8mL 2-8°C
Coated Plate Goat anti-Mouse IgG, 96 wells 2-8°C

Procedure Summary

  1. Prepare standard solutions, samples, and reagents according to the kit instructions.
  2. Add Neutralizing Buffer, HCl, standards, or samples to the appropriate wells.
  3. Add cGMP-HRP conjugate and anti-cGMP antibody to each well (excluding controls).
  4. Incubate at room temperature for 2 hours.
  5. Wash the plate 4 times with Assay Buffer and remove residual liquid.
  6. Add TMB Substrate to each well and incubate for 10 minutes.
  7. Add Stop Solution and measure absorbance at 450 nm.

Storage & Notes

  • Store all reagents as instructed in the kit manual.
  • Bring all reagents to room temperature before use.
  • Avoid cross-contamination by using clean pipette tips and washing thoroughly.
  • Handle Stop Solution with care as it is corrosive.

For more information or technical support, contact AtaGenix customer service.

Choose AtaGenix to enhance your research!

Messages